The Model P110C variable reluctance absolute or sealed pressure transducer is designed specifically for the petro-chemical industry. All welded construction reduces long term drift and hysteresis and increases accuracy. The pressure cavity is designed with no entrapment areas to facilitate cleaning. This unit features Tavis Corporations highly stable, reliable, accurate 4 to 20 mA electronics.
Unit of Measure
General Specifications
Pressure Range |
N/A 0 to 100 through 0 to 10000 psi |
Proof Pressure |
N/A 200% F.R. to 10000 psi max. |
Max. Weight |
N/A 3 lb |
Sensor Type |
N/A Variable Reluctance |
Media |
N/A Liquids or gases compatible with 17-4 PH SS |
External Materials |
N/A 17-4 PH and 300 Series SS |
Electrical
Input Voltage (At the Transducer) |
N/A 17 to 50 VDC |
Power Supply Voltage |
N/A Transducer Input Voltage + (0.02 x load) |
Output Voltage |
N/A 4 to 20 mA |
Max. Output Noise |
N/A 1.0% F.S. peak |
Load Resistance |
N/A (min. Supply voltage - 17) ˜ 0.02 |
Insulation Resistance |
N/A 100 megohms min. at 100 VDC |
Adjustment Range |
N/A Span: ± 2% F.S. min. Zero: ± 2% F.S. min. |
Performance
Static Error Band |
N/A Ranges 5000 psi and up : ± 0.5% F.S. max. Ranges less than 5000 psi : ± 0.2% F.S. max. |
Max. Temperature Error |
N/A ± 0.75% F.S. |
Max. Regulation |
N/A 0.025% F.S. per volt |