Pressure Range |
N/A 0 to 100 through 0 to 10000 psi |
Proof Pressure |
N/A 200% F.R. to 10000 psi max. |
Max. Weight |
N/A 3 lb |
Sensor Type |
N/A Variable Reluctance |
Media |
N/A Liquids or gases compatible with 17-4 PH SS |
External Materials |
N/A 17-4 PH and 300 Series SS |
Input Voltage (At the Transducer) |
N/A 17 to 50 VDC |
Power Supply Voltage |
N/A Transducer Input Voltage + (0.02 x load) |
Output Voltage |
N/A 4 to 20 mA |
Max. Output Noise |
N/A 1.0% F.S. peak |
Load Resistance |
N/A (min. Supply voltage - 17) ˜ 0.02 |
Insulation Resistance |
N/A 100 megohms min. at 100 VDC |
Adjustment Range |
N/A Span: ± 2% F.S. min. Zero: ± 2% F.S. min. |
Static Error Band |
N/A Ranges 5000 psi and up : ± 0.5% F.S. max. Ranges less than 5000 psi : ± 0.2% F.S. max. |
Max. Temperature Error |
N/A ± 0.75% F.S. |
Max. Regulation |
N/A 0.025% F.S. per volt |