Print Back
The Model P24C high accuracy, low differential pressure transducer is designed for applications which demand a high degree of accuracy at extremely low differential pressures. This unit features Tavis Corporation s two wire 4 to 20 mA electronics. A specially designed heater is incorporated to eliminate any errors which may be introduced by ambient temperature variations.
Unit of Measure

General Specifications

Pressure Range

0 to 0.10 H2OD through 0 to 100 H2OD

Proof Pressure

200% rated range

Max. Line Pressure

20 psia

Max. Weight

12 lb

Sensor Type

Variable Reluctance

Media

Compatible with 410 SS, 316, and Iconel

Electrical

Input Voltage

17 to 50 VDC

Output Voltage

4 to 20 mA

Max. Output Noise

0.5% F.S. P-P

Load Resistance

0 to 500 ohm

Insulation Resistance

100 megohms min. at 100 VDC

Power Required By Heater

50 watts at 110 VAC

Time To Warm Up

2.0 hrs

Performance

Max. Total Error Band

±0.5% F.S.

Max. Regulation

0.02% per volt

Resolution

Infinite

Environmental

Temperature Range

0ºF to 130ºF

Shock

100 g s, 11 ms

Humidity, Altitude, Rain, Fungus, Salt Spray, Sand and Dust

Unaffected with pressure ports sealed

Features

N/A

  • High Accuracy
  • Long Term Stability
  • Stable Calibration
  • Rugged High
  • Reliability Electronics