Print Back
Are you tasked with monitoring the liquid level in an open water reservoir, river, or in a closed or vented tanking system? Tavis transducers have been providing liquid level measurements for anything from wine fermentation tanks to remote lakes. Flush diaphragm models have been designed to bolt directly onto tank walls. Ported transducers are easily plumbed into manifolds and processing vats. Even submersible styles have been developed to reside directly in the liquid, whether an open water body or a down-hole well. Vent lines can be used to provide atmospheric or ullage pressure reference for very accurate liquid level data. Tavis Technical Bulletin #103 may be of interest to those looking for additional information on tank gauging and liquid level measurement.

High reliability liquid level measurements with Tavis transducers/transmitters have featured:
  • High corrosion resistance stainless steels and Inconels
  • Either 2- and 3-wire current loop (4-20 mA) outputs or 4-wire voltage outputs
  • Submersible configurations with vented reference ports
  • Liquid intrusion into a reference port will not damage the all-metallic welded gage
  • Underwater electrical/data cables
  • Small diameter, down-hole well capability
  • Self-clearing diaphragm ports for clog-free operation
  • Custom mounting provisions
Unit of Measure

General

Pressure Range1 N/A 0 - 0.1 psi to 0 - 6.0 psi 0 - 6.1 psi to 0 - 500 psi

Line Pressure

N/A 0 - 350 psi (for =10 psi full scale) 0-800 psi (for >10 psi full scale) Line pressure will affect zero and span accuracy

Proof Pressure

N/A 200% FS or 20 psi, whichever is greater

Sensor Type

N/A Variable Reluctance

Weight

N/A 25 oz Nominal

Wetted Materials

N/A 17-4 PH SST

Construction

N/A Anodized Aluminum Base and Cover, 17-4 PH SST Gage (Absolute, Differential, Gage)

Fittings / Ports

N/A Female 1/8 - 27 NPT

Electrical

Input Voltage

N/A 16 - 50 VDC

Output Signal

N/A 0 - 10 VDC

Power/Current

N/A 3.5 mA Nominal

Electrical Interface

N/A Bendix PT02A8-4P

Reverse Polarity Protection

N/A No

Insulation

N/A >100 MΩ @ 50 VDC

Output Impedance

N/A 100 Ω Max

Environmental

Compensated Temps

N/A 30 °F to +130 °F (-65 °F to +225 °F Operating)

App Media

N/A Non-Corrosive Liquids or Gases, Bubbler Applications

Performance

Static Error Band2 N/A ±0.3% FSO Max

Thermal Error1

N/A ±2.0% FSO Max
  • 1 The designs above are intended to convey just a few capabilities previously used in liquid level monitoring for discussion purposes. Tavis specializes in custom configurations and capabilities for your specific application. Discuss your liquid level requirements with our engineers for your specific application.
  • 2 Many error band definitions and limits are possible, and these actual error bands are too specific to delineate herein. A clear definition and understanding of any error band is critical, and many manufacturers’ published errors or accuracies can be very misleading. Please consult Tavis regarding your specific error band requirements.