Pressure Transmitters for Submersible / Liquid Storage
All Categories
Are you tasked with monitoring the liquid level in an open water reservoir, river, or in a closed or vented tanking system? Tavis transducers have been providing liquid level measurements for anything from wine fermentation tanks to remote lakes. Flush diaphragm models have been designed to bolt directly onto tank walls. Ported transducers are easily plumbed into manifolds and processing vats. Even submersible styles have been developed to reside directly in the liquid, whether an open water body or a down-hole well. Vent lines can be used to provide atmospheric or ullage pressure reference for very accurate liquid level data. Tavis Technical Bulletin #103 may be of interest to those looking for additional information on tank gauging and liquid level measurement.
High reliability liquid level measurements with Tavis transducers/transmitters have featured:
High reliability liquid level measurements with Tavis transducers/transmitters have featured:
- High corrosion resistance stainless steels and Inconels
- Either 2- and 3-wire current loop (4-20 mA) outputs or 4-wire voltage outputs
- Submersible configurations with vented reference ports
- Liquid intrusion into a reference port will not damage the all-metallic welded gage
- Underwater electrical/data cables
- Small diameter, down-hole well capability
- Self-clearing diaphragm ports for clog-free operation
- Custom mounting provisions
Unit of Measure
Items |
/Asset/Pressure-Transmitter-10391.JPG 10391 |
/Asset/Pressure-Transmitter-104XX.JPG 10461 |
/Asset/Pressure-Transmitter-10477.JPG 10477 |
/Asset/Pressure-Transmitter-10544.JPG 10544 |
||||
Pressure Range1 | N/A 0 - 37 inches H2OD | N/A 0 - 0.1 psi to 0 - 6.0 psi 0 - 6.1 psi to 0 - 500 psi | N/A 0 - 5 M H2OD to 0 - 40 M H2OD | N/A 0 - 1 psi to 0 - 300 psi | ||||
Line Pressure | N/A 2.25 - 17.18 psia | N/A 0 - 350 psi (for =10 psi full scale) 0-800 psi (for >10 psi full scale) Line pressure will affect zero and span accuracy | N/A | N/A | ||||
Proof Pressure | N/A 75 psig | N/A 200% FS or 20 psi, whichever is greater | N/A 200% FS | N/A 150% FS or 15 psi, whichever is greater | ||||
Burst Pressure | N/A 125 psig | N/A | N/A 500% FS | N/A | ||||
Sensor Type | N/A Variable Reluctance | |||||||
Weight | N/A 32 oz Max | N/A 25 oz Nominal | N/A 35 oz Nominal | N/A 10 oz Max (without cable) | ||||
Wetted Materials | N/A 17-4 PH SST | N/A 17-4 PH SST | N/A 17-4 PH SST 321 CRES | N/A 304L CRES Delrin Inconel 625 Urethane | ||||
Construction | N/A Differential (Ullage) Reference Tube, TIG Welded 17-4 PH SST Flush Diaphragm with Integral Flange | N/A Anodized Aluminum Base and Cover, 17-4 PH SST Gage (Absolute, Differential, Gage) | N/A TIG Welded Gage/Case, Brazed Vent Port Tube, Flush Diaphragm with Threaded Base Mounting Plate | N/A 1-inch O.D Max, TIG Welded Gage/Case, Urethane Cable with Integral Vent Tube | ||||
Fittings / Ports | N/A N/A - Flush Diaphragm with Flange | N/A Female 1/8 - 27 NPT | N/A 7/16 - 20 UNF-2B per SAE/MS 16142 Vent Port, Flush Diaphragm with Slots at Base | N/A Flush Diaphragm with Perforated Nose End | ||||
Input Voltage | N/A 20.5 - 32.2 VDC | N/A 16 - 50 VDC | N/A 8 - 16 VDC | N/A 20 - 40 VDC | ||||
Output Signal | N/A 0.5 - 5.5 VDC | N/A 0 - 10 VDC | N/A SDI-12 RS-232 Analog Possible | N/A 4 - 20 mA | ||||
Power/Current | N/A 20 mA Max | N/A 3.5 mA Nominal | N/A 1 - 35 mA (Digital) | N/A 4 - 20 mA | ||||
Electrical Interface | N/A MIL-C-26482/MSFC 40M39569 (10-6) | N/A Bendix PT02A8-4P | N/A Seacon LMG-4-BCL Underwater or Equivalent | N/A 2-wire urethane cable with integral vent tube - various lengths | ||||
Reverse Polarity Protection | N/A Yes | N/A No | N/A No | N/A No | ||||
Insulation | N/A >100 MΩ @ 50 VDC | N/A >100 MΩ @ 50 VDC | N/A >50 MΩ @ 50 VDC | N/A >50 MΩ @ 50 VDC | ||||
Output Impedance | N/A 1000 Ω Max | N/A 100 Ω Max | N/A | N/A | ||||
Compensated Temps | N/A 32 °F to +110 °F (-65 °F to +165 °F Operating) | N/A 30 °F to +130 °F (-65 °F to +225 °F Operating) | N/A 0 °C to +50 °C | N/A 0 °F to +120 °F | ||||
Vibration | N/A | N/A | N/A 2 g @ 10 - 45 Hz .02 in @ 45 - 100 Hz 10 g @ 100 - 1000 Hz | N/A | ||||
Shock | N/A 10 g 11 ms Half Sine | N/A | N/A 100 g 11 ms Half Sine | N/A 20 g 11 ms Half Sine | ||||
App Media | N/A Waste Water | N/A Non-Corrosive Liquids or Gases, Bubbler Applications | N/A Fresh Water Sea Water | N/A Fresh Water | ||||
Static Error Band2 | N/A ±1.0% FSO Max | N/A ±0.3% FSO Max | N/A | N/A ±0.3% FSO | ||||
Thermal Error2 | N/A ±2.0% FSO Max | N/A ±2.0% FSO Max | N/A | N/A | ||||
Total Error Band (TEB)2 | N/A | N/A | N/A ±0.1% FSO Max (Digital) | N/A ±1.5% FSO | ||||
Frequency Response3 | N/A | N/A | N/A 5 s (Digital) | N/A | ||||
|