The Model P4 pressure transducer features adjustable zero and full scale. Utilizing all welded construction and extremely stable electronics, this transducer provides highly accurate pressure measurements in harsh environments. The Model P4 is available in absolute and differential pressure models with input to output isolation.







  • All Tavis transducers can be supplied for corrosive media applications. Materials used for this purpose are 17-4PH SS, 17-7PH SS and Iconel . Specify model P104 for this feature.
  • Closer tolerances and higher temperature operation may be supplied. Consult factory for special requirements.
  • Add 0.5 inches to length for absolute units with ranges less than 5 psia.
Unit of Measure

General Specifications

Pressure Range

N/A 0 to 1 psi through 0 to 350 psi

Proof Pressure

N/A 20 psi or 200% F.S. (Higher proof pressures available. Consult factory)

Line Pressure

N/A 20 psia or 200% F.S. (Higher line pressures available. Consult factory)

Max. Weight

N/A 6 oz

Sensor Type

N/A Variable Reluctance

Media

N/A Liquids or gases compatible with 410 SS, 17-4 PH SS and Iconel

Electrical

Input Voltage

N/A 20 to 40 VDC

Max. Input Current

N/A 10 mA

Output Voltage

N/A 0 to 5 VDC

Max. Output Impedance

N/A 100 ohm

Max. Output Noise

N/A 15 mv P-P

Insulation Resistance

N/A 100 megohms min. at 100 VDC

Isolation Resistance

N/A 100 megohms min. at 100 VDC

Adjustment Range

N/A Span: ± 2.0% F.S. min. Zero: ± 2.0% F.S. min.

Performance

Max. Static Error Band

N/A ± 0.5% F.S. (2)

Hysteresis

N/A ± 0.1% F.S. nom.

Repeatability

N/A ± 0.1% F.S. nom.

Max. Temperature Error

N/A ± 2.0% F.S. (2)

Frequency Response

N/A Flat ±5% to 250 Hz

Max. Regulation

N/A 0.05% F.S. per volt

Resolution

N/A Infinite

Environmental

Temperature Range

N/A Compensated: -65ºF to +165ºF (2) Operating: -65ºF to +200ºF

Vibration

N/A 20 g s Peak to 2000 Hz

Shock

N/A 100 g s, 11 ms

Humidity, Altitude, Rain, Fungus, Salt Spray, Sand and Dust

N/A Unaffected

Features

N/A

  • High Accuracy
  • Long Term Stability
  • Stable Calibration
  • All Welded Construction