Print Back
Sea water, fresh water, air, fuel and oil pressures are monitored by Tavis transducers every day, and on some of the most sophisticated land and sea-based vehicles in the world. Our customized acceptance testing assures that whether at a cold depth of 100 fathoms or a dusty speed of 100 mph, all your pressure measurements are reliable and accurate.




Tavis land and sea vehicle applications involve such features and capabilities as:
  • High corrosion resistance
  • Small dynamic pressure signal detection amid very high static pressures
  • User-defined, tuned frequency response characteristics
  • Contamination tolerance and particle traps
  • Specialized shielding and filtering for operation near strong EMI sources
  • 2- and 3-wire current loop outputs and 4-wire voltage outputs
No-6-Submarine-Mil-Veh
Unit of Measure
Items Submarine-Military-Vehicles-10292
10292
Submarine-Military-Vehicles-10369
10369
Submarine-Military-Vehicles-10105
10105
Submarine-Military-Vehicles-10055
10055
Pressure Range1 N/A 0 - 10 to 0 - 1000 psig N/A 0 - 265 psia Static 0 - 40 inches H2O Dynamic N/A 0 - 150 psia to 0 - 7500 psia 0 - 50 psig N/A 0 - 125 psia
Line Pressure N/A N/A 0 - 265 psia N/A N/A
Proof Pressure N/A 200% FS psia N/A 877 psia N/A 300% FS or 10,000 psia N/A 188 psia
Burst Pressure N/A N/A N/A 304 psia341 psig N/A
Sensor Type N/A Variable Reluctance
Weight N/A 10 oz Max N/A 4 lb Max N/A 4 lb Max N/A 8 oz Max
Wetted Materials N/A 410 SST N/A 17-4 PH SST N/A 17-4 PH SST 321 CRES N/A 17-4 PH SST
Construction N/A Sealed Gage TIG Welded 410 SST Flange Feature N/A Flange Feature TIG Welded Flush Diaphragm N/A TIG Welded Gage/Case Adjustment Pots Brazed Mounting Feet Vented Gage or Absolute N/A TIG Welded Gage/Case Adjustment Pots Thread Mount Lockwire Holes
Fittings / Ports N/A 1/4 - 18 NPT Fitting N/A N/A - Flush Diaphragm N/A MS16142 7/16 - 20 Female with 3/4 Hex N/A 3/4 - 16 UNF-3A port with 1.50 Hex
Input Voltage N/A 17 - 35 VDC N/A 5 - 10 VDC N/A 26 - 30 VDC N/A 24 - 32 VDC
Output Signal N/A 4 - 20 mA N/A Dual Output 0 - 2 VDC 0 - 3 Vpp N/A 4 - 20 mA N/A 0.0 - 5.0 VDC
Power/Current N/A .56 W Nominal N/A 0.4 mA N/A N/A 10 mA Nominal
Electrical Interface N/A Connector MS33800-1 N/A Glass-to-Metal Header with 8 Terminal Pins N/A MS3143HS-10SLY-3P N/A PT1Y-10-6P
Reverse Polarity Protection N/A Yes N/A No N/A Yes N/A Yes
Insulation N/A >100 MΩ @ 100 VDC N/A >100 MΩ @ 100 VDC N/A >50 MΩ @ 100 VDC N/A >100 MΩ @ 100 VDC
Output Impedance N/A N/A Max 300 Ω N/A N/A =600 Ω
EMI N/A N/A Magnetic Shield N/A Inductor/ Capacitor Filter N/A
Compensated Temps N/A (Transient +350 °F) -65 °F to +165 °F N/A 28 °F to +90 °F (-65 °F to +160 °F Operating) N/A 15 °C to 35 °C N/A 30 °F to +150 °F
Vibration N/A 25 grms N/A N/A MIL-STD-167, Type I N/A 20 g pk to 2000 Hz
Shock N/A 1000 g 11 ms Half Sine N/A 5000 g @ 0.2 ms 500 g @ 40 ms Half Sine N/A MIL-S-901 High Shock N/A 20 g 11 ms Half Sine
App Media N/A Lubrication Oil N/A Sea Water N/A Air Fresh Water Sea Water N/A Sea Water
Static Error Band2 N/A ±0.5% FSO N/A N/A N/A ±0.08% FSO ±0.5% FSO N/A ±0.25% FSO
Thermal Error2 N/A ±4.0% FSO Max N/A AC ±3% FS DC ±3% FS N/A ±0.013% FS/°C N/A ±1.5% FSO
Total Error Band (TEB)2 N/A N/A AC ±3% FS DC ±3% FS N/A N/A
Frequency Response N/A N/A .0005 Hz to .25 Hz N/A Max 20 ms N/A Flat ±5% to 500 Hz
  • 1 The designs above are intended to convey just a few capabilities previously used in critical flow systems for discussion purposes. Tavis specializes in custom configurations and capabilities for your specific application. Discuss your vehicle requirements with our engineers for your specific flow control needs.
  • 2 Many error band definitions and limits are possible, and these actual error bands are too specific to delineate herein. A clear definition and understanding of any error band is critical, and many manufacturers’ published errors or accuracies can be very misleading. Please consult Tavis regarding your specific error band requirements.