Tavis satellite transducers have provided propulsion measurements for journeys to orbit other planets, while other Tavis instruments have actually landed on planetary surfaces or measured pressures as the spacecraft plummets through other solar system atmospheres.
Previous hardware for missions to Mars, Jupiter, Venus and the Moon have featured one or more of the following:
Previous hardware for missions to Mars, Jupiter, Venus and the Moon have featured one or more of the following:
- Very low barometric pressure measurements with high proof
- Severe thermal environments
- Tether cable for thermal separation between gage and electronics
- Low power consumption
- Long-term stability over thermal environments
- Ice, sand, dust immunity
- High-cycle power on-off
- Spores bake-out
- Zero Outgassing
Unit of Measure
General
Pressure Range1 | N/A 0 - 5 psia |
Proof Pressure |
N/A 20 psia |
Burst Pressure |
N/A >>20 psia |
Sensor Type |
N/A Variable Reluctance |
Weight |
N/A 13 oz Max |
Wetted Materials |
N/A 17-4 PH SST 410 SST Inconel 600 |
Construction |
N/A TIG Welded Gage Thermally / Electrically Isolated Feet 12-ft Tether to Electronics |
Fittings / Ports |
N/A 1/4 Flared Tube Fitting |
Electrical
Input Voltage |
N/A 24 - 32 VDC |
Output Signal |
N/A 0.0 - 4.0 VDC |
Power |
N/A 10 mA Max |
Electrical Interface |
N/A MSFC 40M39569 (10-6) Connector |
Reverse Polarity Protection |
N/A Yes |
Isolation |
N/A >10 MΩ @ 50 VDC |
Output Impedance |
N/A <1000 Ω |
- 1 The designs above are intended to convey just a few capabilities previously used on interplanetary craft for discussion purposes. Tavis specializes in custom configurations and capabilities for your specific application. Discuss your application requirements with our engineers for your exploration science needs.
- 2 Many error band definitions and limits are possible, and these actual error bands are too specific to delineate herein. A clear definition and understanding of any error band is critical, and many manufacturers’ published errors or accuracies can be very misleading. Please consult Tavis regarding your specific error band requirements.
- 3 Frequency Response given is for electronics only. Actual frequency response will depend on pressure range and media.