In addition to our customers making ΔP measurements across an orifice with our differential transducers, Tavis makes very accurate flow sensors with integral venturi tubes. In fact, the Space Station is chock full of Tavis flowmeters for environmental control and life support systems. Our Variable Reluctance technique and construction allow for very high line pressures even with low flow rates. Some of our more customized flowmeters have dual flow range capability.
Tavis Venturi flowmeters are used in applications with characteristics such as:
Tavis Venturi flowmeters are used in applications with characteristics such as:
- Custom venturi designs for specific flow requirements
- Dual gage low/high flow rates
- High line pressure
- Output signal linear with either pressure or flow
- No rotating/moving parts
- Continuous analog output; flow is not sampled or digitized
- Weld-mount, flange-mount, fitting-mount interface with system plumbing
- 4 - 20 mA and 0/1-5 VDC outputs
Unit of Measure
General
Flow Range1 | N/A (0.97 psid & 1.42 psid loss at max flow) 498 - 3108 lb/hr705 - 4409 lb/hr |
Line Pressure |
N/A 17.8 to 121 psia25 to 171 psia |
Line Proof Pressure |
N/A 182 psia256 psig |
Line Burst Pressure |
N/A 304 psia341 psig |
Sensor Type |
N/A Variable Reluctance |
Weight |
N/A Max 3.31 lb |
Wetted Materials |
N/A 17-4 PH SST 321 CRES |
Construction |
N/A TIG Welded Gage/Venturi Assy |
Fittings / Ports |
N/A .75" DIA Inlet/Exit |
Electrical
Input Voltage |
N/A 24 - 32 VDC |
Output Signal |
N/A 0.8 - 5.0 VDC (linear with flow) |
Power/Current |
N/A Max 25 mA |
Electrical Interface |
N/A Mates with D38999/2611-98SN 6-Pin |
Reverse Polarity Protection |
N/A Yes |
Isolation |
N/A >50 MΩ @ 100 VDC |
Output Impedance |
N/A ≤150 Ω |
- 1 The designs above are intended to convey just a few capabilities previously used in critical flow systems for discussion purposes. Tavis specializes in custom configurations and capabilities for your specific application. Discuss your flow system requirements with our engineers for your specific flow control needs.
- 2 Many error band definitions and limits are possible, and these actual error bands are too specific to delineate herein. A clear definition and understanding of any error band is critical, and many manufacturers’ published errors or accuracies can be very misleading. Please consult Tavis regarding your specific error band requirements.
- 3 Frequency Response given is for electronics only. Actual frequency response will depend on pressure range and media.