The Nuclear Power Industry trusts Tavis for some of their critical air flow controls, with very low differential pressure transducers that have been seismically qualified. So do oil companies measuring high, down-hole pressures at hot temperatures. Conventional power companies also call on Tavis for their special sensing needs. When a process requires a rugged, bulletproof, install-it-and-forget-it measurement that the cheap sensors can’t handle, a Tavis transducer or transmitter is the right sensor investment. This is especially true for applications that must monitor very low delta pressures.


Power and Industry customers have looked to Tavis for custom sensors that offer:
  • Integral radiation shielding
  • Internal heater-controlled for added accuracy
  • Either 2- and 3-wire current loop (4-20 mA) outputs or 4-wire voltage outputs
  • 110 VAC operation
  • Very Low Delta Pressure, some with high line and overpressure capability
  • Fully sealed environmental enclosures or all-welded designs
  • Seismic Qualification
  • Acoustic tolerance
Unit of Measure

General

Pressure Range1 N/A 0 - 0.1 psid to 0 - 100 psid

Proof Pressure

N/A 200% FS or 20 psi, whichever is greater

Burst Pressure

N/A >>200% FS

Sensor Type

N/A Variable Reluctance

Weight

N/A 16 oz Max

Wetted Materials

N/A 17-4 PH SST
Inconel 600/625
Hy-Mu 80

Construction

N/A TIG Welded Gage/Case Brazed Fittings Zero and Span Adjustment Pots

Fittings / Ports

N/A MS33656-4 Flared Tube Fittings

Electrical

Input Voltage

N/A 20 - 40 VDC

Output Signal

N/A 0.0 - 5.0 VDC

Power/Current

N/A 10 mA Max

Electrical Interface

N/A Bendix/MS3116 PT1Y-10-6P

Reverse Polarity Protection

N/A No

Insulation

N/A >100 MΩ @ 100 VDC

Output Impedance

N/A 100 Ω Max

Environmental

Compensated Temps

N/A -65 °F to +165 °F

Vibration

N/A 35 g pk to 2000 Hz

Shock

N/A 100 g 11 ms Half Sine

App Media

N/A Gases Liquids (above freezing)

Performance

Static Error Band2 N/A ±0.5% FSO

Thermal Error

N/A ±2% FSO
Frequency Response3 N/A Flat ±5% to 500 Hz
  • 1 The designs above are intended to convey just a few capabilities previously used in industrial settings for discussion purposes. Tavis specializes in custom configurations and capabilities for your specific application. Our engineers will be happy to assist you with your unique measurement requirements.
  • 2 Many error band definitions and limits are possible, and these actual error bands are too specific to delineate herein. A clear definition and understanding of any error band is critical, and many manufacturers’ published errors or accuracies can be very misleading. Please consult Tavis regarding your specific error band requirements.
  • 3 Frequency Response given is for electronics only. Actual frequency response will depend on pressure range and media.